incinerators for sale, incinerators The Helios 2.0 Solid Waste Incinerator Model (previously known as the Vulcan 2.0 Incinerator) is a large scale waste disposal system designed to accommodate solid waste streams generated from industrial facilities, businesses, waste management plants, and airports. Constructed as a dual chamber incineration system, these models are better able to control incineration, temperatures, and emissions generated from the unit. This creates a complete system that can handle the safe disposal of trash, debris, medical waste, animal waste, and other combustible materials.

Our Incinerators for sale here are built with two chambers and include a complete control system. This system regulates the temperature of the unit and systematically adds air to meet the needs of your waste type. Questions? Call our team at +1-772-646-0597. Request a Quote

Helios 2.0 Technical Specifications USA Made

System Specifications
Flyers: Helios A 2.0 Incinerator Flyer(pdf)
System Capacity:
  • 2.0 MMBtu/hr (2.11 kjoule/hr) waste combustion
  • 210-320 lb/hr (95-145kg/hr) processing capacity for mixed waste streams
  • Average gross HHV of 5500-8500 Btu/lb.
Batch Capacity: Approx. 3 yd3 (2.29 m3) per batch cycle
Intermittent Feed: (with optional loader) 1.26-2 yd3/hr (1.6-1.8 m3/hr) up to 8 hrs/day
Electrical Requirements: Single point - 230/460V, 3ø, 60 Hz, 25/15 amp (40/25 amp w/optional loader)
Overall Length: 11’-6” (2896mm) batch system w/o loader20’-6”(5639mm) w/optional loader system
Overall Width: 9’-3” (2820mm)
Overall Height: (without stack) 10’-0” (3048mm)
Approx. Weight: 16,500 lbs. (7500 kg)

*System Capacity: The rated system capacity for this unit is 1.5 MMBtu/hr or 175-250 lb/hr (80-114 kg/hr). The second number is listed as a range. Where your products fall within that range will vary depending on the type and amount of waste being incinerated.

For all solid waste, each item is rated with a designated BTU value. Knowing the waste type and intended quantity will help our team determine which side of the range your incinerator will be able to work towards.

Request a Quote
Questions? Call our specialists at
+1-772-646-0597

Helpful Links

Solid Waste Incinerator Dual Chamber System

  Primary Chamber Secondary Chamber
Type: Fixed Hearth, with controlled under-fire air injection Cyclonic thermal oxidizer with 1+ sec. r/t @ 1600°F (850oC)

Chamber Volume:

100 ft³ 59.5 ft³ (std.)
Hearth Area: 20 ft²  
Burner Capacity: 0.6 MMBtu/hr. (Hi-Lo-Off control) 1.43 MMBtu/hr. (modulating, excess air control)
Construction: Skid: 6”, 10.5#/ft., A36 channel  
Construction: Shell 0.250" thick, A36 plate 0.250" thick, A36 plate
Construction: Lining 4", 3000°F 750 psi, (Plicast 3100KK or equal) 3", 2800°F 750 psi, (Plicast 3100KK or equal)
Construction: Insulation 1" 1900°F Fiber
(ASTM C612093, type V)
1" 1900°F Fiber
(ASTM C612093, type V)
Approximate Weight: 9,000 lbs. (4090 kg) 6000 lbs. (2727 kg)

Combustion Air Specifications
Combustion Air: Supply to Burners, Under Fire, and Secondary Air Injection
3 HP, 230/460 V, 3 dia. 60 Hz
850 cfm @ 18” W.C. pressure

Exhaust Breaching Specifications
Shell Construction: 10 gauge, A36 Carbon Steel
Lining: 3" 2400° F, 175 PSI
(Plicast AL-Tuff LWI-24 or equal)
Weight: 155 lbs./ft (70.45 kg/ft)
Request a Quote
Questions about Helios Incinerators?

Call our specialists at

+1-772-646-0597

System Controls

incineratorsTypical controls found on these incinerators for sale include a Siemens S-7 series PLC with touch screen operator interface and the following features:

  • Primary & Secondary Chamber Temperature Control
  • Temperature Actuated Fuel and Air Control
  • Burner Interface, Status and Reset Access
  • System Status and Alarm Display
  • Hydraulic System Control (Applicable with Optional Loader)

    ** Discrete, UL, CSA, FM & IRI burner monitoring/control w/U.V. flame supervision provided for each burner.


Optional Loader Types

  • Type: Hydraulic ram feed (optional cart tip hopper load available)
  • Hopper volume: 14 cu. ft. (.4 m3)
  • Power unit: 5hp, 230/460 V, 3 dia, 1800 psi
  • Hydraulic cylinders: 2500 psi: Charge door - two 2” bore, 30” stroke
  • Charging ram- two 2” bore, 36” stroke
  • Hopper lid - one 2.5” bore, 16” stroke
  • Hopper loader - two 2.5” bore, 18” stroke
  • Charging frequency: 20 minutes, up to 3 times per hour
  • Approx. weight: 5,000 lbs. (2273 kg)

Optional Guardian-OCS: Oxygen monitoring combustion air control (Increases fuel efficiency of the system by 25% & provides dynamic combustion control to prohibit upset conditions)


Thermal Oxidation Incinerator Benefits

  • Advanced Cyclonic Secondary Combustion Chamber
  • Thermal Oxidation of Combusion Gases (over 1 second retention std.)
  • Utilizes Weight Saving Refractory Materials
  • Modular Constructions
  • Easy Set Up and Installation
  • Ongoing System Maintenance

For additional sizes, processing capacities, or other disposal options, please check out our range of Incinerators for Sale.

Request a Quote

If you have questions about any of our Helios Incinerators for sale, give us a call at +1-772-646-0597 or request a price quote.